Management of SCSR in mines
Management of self-contained self-rescuers in mines
ANNEXURE 2: Guidance Note 2 (mandatory) Leak testing (for lamp-rooms only)
The following criteria must be implemented:
Leak testing must meet the requirements of SANS 1737 .
Leak test shall adhere to a series of physical performance and basic specifications.
A benchmark must be set stipulating minimum pressure measurements and standard evacuation times.
Leak test parameters:
For shallow mining (i.e. mines less than 500m in depth, e.g. coal mines)
Test pressure = -70mbar or -7000Pa or -7kpa or -0.07bar
For deep mining (i.e. mines deeper than 500m in depth, e.g. gold and some platinum mines)
Test pressure = -200mbar or -20000Pa or -20kpa or -0.2bar
Leak test intervals should be indicated, based on risk assessment, but should be performed at least bi-annually.